Neware battery tester battery testing system to do battery life cycle testing by Battery Charging and Discharging
Summary
Neware offers battery testing equipment for single battery and capacitor testing basic charge discharge cycling,simulating complex real world applications such as pulse testing,simulation driving testing and other custom profiles.
Neware offers this model single battery and capacitor testing equipment to battery Lab and battery manufacture .User can create testing profiles at client software which installed on the PC used to controlled all battery testing equipment.Client software has data basic to manage all real-time monitoring,user also can back up data during testing.Neware offers data analyzer software for data analysis.
Applications&Features
Pulse Testing
Life Cycle Testing
Production Line Testing
Specific Capacity Testing
Charge/Discharge Testing
Battery&Supercapacitor Testing
General Specification
Cycle Times:1~65535
Testing Accuracy:0.1% of FS
Data Record Frequency:10Hz
Data Export Format:Excel/TXT
-
Connection for PC:TCP/IP(Ethernet)
The series Battery Testing Equipment is based on Neware forth-generation testing system,and was introduced into the market in 2008,and widely used at Lab and battery manufacture.Battery Testing System generally be divided as hardware and client software,software is installed at computer to control hardware,users could edit battery testing program to charge and discharge battery.
BTS5V10A8CH Technical Specification
Project Index |
Parameter Index | |
Input AC Power |
AC 220V 10% / 50Hz |
|
Input Impedance |
1M |
|
Input Power |
709W |
|
Resolution |
AD:16bit;DA:16bit |
|
Channel Features |
Constant Current&Voltage Source with Independent pairs of Closed-loop Structure |
|
Channel Control Mode |
Independent Control |
|
Voltage |
Voltage Range:0.025V~5V |
|
Lowest Discharge Voltage |
2.5V |
|
Accuracy |
0.1% of FS |
|
Stability |
0.1% of FS |
|
Current |
Current Range:500mA~10A |
|
Cut Off Current |
20mA |
|
Accuracy |
0.1% of FS |
|
Stability |
0.1% of FS |
|
Power |
Each Channel Max. Output:50W |
|
Stability |
0.2% of FS |
|
Time |
Current Rise Time:Current upto (10%-90%) ,hardware rise time:20ms |
|
Step Time Range |
1sSingle Step Time Range365*24 h; Support Time Form: 000000:00(hminsms) |
|
Data |
Record Condition:Min. Record Time:0.1s |
|
Min. Record Voltage:10mV | ||
Min. Record Current:20mA | ||
Record Frequency:10Hz | ||
Charge |
Charge Mode |
Constant Current ChargeConstant Voltage ChargeConstant Power ChargeConstant Current and Constant Voltage Charge |
End Conditon |
VoltageCurrentRelative TimeCapacity Relative Voltage | |
Discharge |
Discharge Mode |
Constant Current DischargeConstant Power DischargeConstant Resistance Discharge |
End Condition |
CurrentVoltageRelative TimeCapacity Relative Voltage |
BTS5V10A this model battery testing system have two testing range;Each of units have 8 channel;Neware will offer rack to hold BTS5V10A and clamps to assistance connect battery as picture below: